We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for EMI Test System.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

EMI Test System×マイクロニクス - List of Manufacturers, Suppliers, Companies and Products

EMI Test System Product List

1~13 item / All 13 items

Displayed results

[Application Case] Introduction of MR2300 User Case

Japan Cash Machine Co., Ltd., which manufactures currency processing equipment and other related products.

At Japan Cash Machine Co., Ltd. (JCM), we manufacture and sell currency processing equipment, financial-related devices, cash registers, and gaming-related equipment. Our currency processing machines are used in over 110 currencies worldwide, and we hold a dominant market share in the North American and European gaming markets. We have cleared all the stringent regulations specific to the industry and obtained numerous licenses. JCM has become synonymous with casino banknote validators and leverages its local support capabilities to thrive in the global market. The MR2300 EMI testing system is chosen by leading companies in this industry. For more details, please contact us or refer to our catalog.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Conducted EMI test system combining third-party LISN and MSA.

[Application Example] By combining other companies' LISN and MSA series, conductive EMI testing for DC power supplies and three-phase power supplies is possible.

The MR2150 system for pre-compliance testing of conducted EMI uses MICRONIX's EMI measurement spectrum analyzer and signal analyzer, and can utilize not only the MICRONIX MPW201B as the LISN but also LISNs from other manufacturers. By using LISNs from other manufacturers, the MR2150 can be used for products with DC power, three-phase power, and power supplies of 250V and 15A or more. 【Product Introduction】 ■ Conducted EMI Test System MR2150 *For more details, please refer to the PDF document or feel free to contact us.*

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

EMC Technology <How to Use Simple Measuring Instruments Effectively>

Technical Data: Simple EMI Test System "EMI Total Test System MR2300"

■Conducted EMI Test System MR2150 A pre-compliance system for conducted EMI (noise terminal voltage) testing. By using this system for debugging evaluation before the official EMC testing at a certified site, development costs can be significantly reduced. ■EMI Total Test System MR2300 Ideal for preliminary compliance testing of official EMI tests, known as "Pre-compliance." This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■EMS Test System MR2350 A pre-compliance EMS test system for radiated immunity testing (IEC/EN61000-4-3). *For more details, please refer to the PDF document or feel free to contact us.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Report on the Compatibility of Measurement Data in an Anechoic Chamber

[Technical Data] EMI Test System MR2300/RF Shielded Room MY5410

■EMI Test System MR2300 Ideal for preliminary compliance testing "Pre-compliance" for official EMI tests. This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber / Shielded Box MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. The MR2300/MY5410 has been developed for pre-compliance use. This enables the measurement of harmonics from switching power supplies in the 40-100MHz range, which was previously difficult. Below are the measurement results obtained with the MR2300/MY5410, compared with results from a 10m anechoic chamber equipped with equivalent facilities using the 3m method.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

On the correlation between a standard EMC anechoic chamber and a simplified EMI testing system 2

Technical Data: Simple EMI Test System R2300

■EMI Testing System MR2300 Ideal for preliminary compliance testing for official EMI tests, known as "Pre-compliance." This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. *For more details, please refer to the PDF materials or feel free to contact us. In Section 1, we explained the differences in measurement results between the standard EMC anechoic chamber (hereinafter referred to as the test site) and the simplified EMI testing system MR2300 (hereinafter referred to as MR2300). In Section 2, we have newly added the shielded tent-type simplified anechoic chamber MY5723 and on-site measurements to the measurement environment. Furthermore, we standardized and changed the antennas in four environments other than the test site to the biconical antenna MAN150B, and we will conduct comparisons based on the differences in measurement environments.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comparison of MR2300 and radiation noise measurement in an anechoic chamber.

[Technical Data] EMI Test System MR2300/RF Shielded Room MY5410

■EMI Testing System MR2300 Ideal for preliminary compliance testing of official EMI tests, known as "Pre-compliance." This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg, suitable for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. We measured the noise emitted by the CNE (Comparative Noise Emitter), which is widely used for the calibration of anechoic chambers, using the MR2300 and the anechoic chamber, and compared the results.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Conductive EMI Test System 'MR2150'

Significantly reduce development costs by conducting debugging evaluations before this test.

The "MR2150" is a pre-compliance system for conductive EMI testing. By using this system for debugging evaluation before the official EMC tests conducted at certified EMC sites, significant reductions in development costs can be achieved. Since the spectrum/signal analyzer, LISN, and PC software are all developed in-house, the overall usability and operational stability of the system have been thoroughly verified. Additionally, each component is reasonably priced, providing a cost-effective testing environment. 【Features】 ■ Provides a reasonable and cost-effective testing environment ■ Handheld spectrum/signal analyzers that can be selected based on budget and performance/features ■ Efficiency improvements in EMI testing through rich software functionalities ■ Excellent portability of the LISN *For more details, please refer to the PDF materials or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Application Case] MR2300 User Case Introduction 2

[Application Example] The MR2300 EMI testing system is used for various products.

This time, we will introduce the case of Company Z, which is engaged in the development, manufacturing, sales, and import/export of electronic musical instruments. (The company name is withheld at their request.) Currently, advanced circuit technology has been introduced into electronic devices for music, and EMI evaluation is required in various fields. 【Product Introduction】 ■ MR2300 EMI Test System *For more details, please refer to the PDF materials or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comparison of MR2300 and radiation noise measurement in an anechoic chamber.

[Technical Data] EMI Test System MR2300 / Anechoic Chamber MY5410MY5410

■EMI Test System MR2300 Ideal for preliminary compliance testing "Pre-compliance" for official EMI testing. This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber / Shielded Box MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. We measured the noise emitted by the CNE (Comparative Noise Emitter), which is widely used for the calibration of anechoic chambers, using the MR2300 and the anechoic chamber, and conducted a comparison of the results.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

On the Correlation Between Standard EMC Anechoic Chambers and Simplified EMI Testing Systems 1

Technical Data: Simple EMI Test System R2300

This report will compare and explain the results of measuring the same DUT in a standard EMC anechoic chamber and a simplified EMI test system MR2300. 【Product Introduction】 ■EMI Test System MR2300 *For more details, please refer to the PDF document or feel free to contact us.*

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The relationship between the noise level at the lower limit of measurable radiated EMI and antenna gain.

In radiation EMI measurements, using antennas with high gain allows for the measurement of lower levels of noise.

■Conducted EMI Test System MR2150 A pre-compliance system for conducted EMI (noise terminal voltage) testing. By using this system for debugging evaluation before conducting the official tests at a certified EMC site, significant reductions in development costs can be achieved. By using a high-gain antenna, lower levels of noise can be measured in radiated EMI (emission) measurements.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Report on the Compatibility of Measurement Data in an Anechoic Chamber

[Technical Data] EMI Test System MR2300/RF Shielded Room MY5410

■EMI Test System MR2300 Ideal for preliminary compliance testing of official EMI tests, known as "Pre-compliance." This is an integrated system that combines our spectrum analyzer technology, anechoic chamber technology, and antenna technology. ■Anechoic Chamber MY5410 An anechoic chamber optimal for large-scale EMI testing. It comes standard with a turntable with a diameter of 756mm and a load capacity of 100kg, designed for large EUTs. *For more details, please refer to the PDF materials or feel free to contact us. The MR2300/MY5410 has been developed for pre-compliance use. This enables the measurement of harmonics from switching power supplies in the 40-100MHz range, which was previously difficult. Below are the measurement results obtained with the MR2300/MY5410, compared with measurements conducted in a 10m anechoic chamber equipped with facilities equivalent to the official site, using the 3m method.

  • Other electronic measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Measurement accuracy of the conductive EMI test system MR2150.

Technical Data: Measurement Accuracy of MR2150 Compared to Compliance System

【Product Introduction】 ■Conducted EMI Test System MR2150 A system for pre-compliance testing of conducted EMI (noise terminal voltage). 1. Importance of EMC Pre-compliance Testing - The significance of EMC pre-compliance testing in product development - Comparison of pre-compliance testing and other EMC evaluation solutions 2. Measurement Accuracy Verification of MR2150 - EMI measurement accuracy of the Spectrum/Signal Analyzer MSA series - Conducted EMI testing of sample EUT - Appropriate measurement methods using MR2150

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration